Ford air charge & engine coolant temperature sensors

Last Updated on July 23, 2024 by Mutiara

Both the ACT and ECT sensors are very similar. Before replacing either one, make sure the rest of the coolant system is in good condition. All of the following items will affect the ACT and ECT:

  • Coolant level
  • Radiator Fan
  • Engine Temperature
  • Water pump and Fan Belts
  • Thermostat
  • Engines general condition
  • Harness and wire general condition

The following variables are exclusive only to the ACT:

  • EGR System
  • Ambient temperature
  • Air Filter
  • Air Filter to Throttle Body Duct

Both the ACT and ECT are thermal transistors, which means they allow less electricity to pass through the sensor the warmer it gets. The ACT & ECT receive the signal return voltage from the EEC, and then allow a certain amount to return back to the EEC. The ACT is mounted into the incoming air stream and changes resistance in response to the temperature of that air. The ECT is in direct contact with the engine coolant flow and changes resistance in response to the temperature of that coolant.

Ford EFI ACT chart.png

Both sensors are very important when calculating fuel ratios and timing curves. This is because of simply chemistry, fuel and spark are constants in the equation. Air is the biggest variable in combustion, it changes density greatly over a range of temperature. So keeping track of the changing temperatures of the incoming air and the engine in which it is burnt becomes very important. But due to their simplicity of design, the ACT and ECT are rarely at fault when problems occur.

Before testing the ACT and ECT or any other EFI component perform a self-test. Trouble codes received during test can be used as a diagnostic tool along with other indicators. To test the sensors you will need a volt meter. You can test the ACT and ECT by back probing the harness while reading the voltage returning to the EEC. Or you can remove the connector completely and test the resistance between the 2 pins.

  • To test the ACT the ambient temperature should be above 50F (10C) to receive acceptable input from the Air Charge Temperature (ACT) sensor during the KOEO and KOER Self-Test. To accomplish this, the engine should be at normal operating temperature.
  • To test the ECT the engine temperature must be greater than 50F (10C) to pass the KOEO Self-Test and greater than 180F (82C) to pass the KOER Self-Test. To accomplish this, the engine should be at normal operating temperature.
Ford EFI ACT diagram.png
Ford EFI ECT pinout.png
FCVoltsK ohms
3021600.120.54
2671310.200.80
2501200.301.18
2301100.361.55
2121000.472.07
194900.612.80
176800.803.84
158701.045.37
140601.357.60
122501.7210.97
104402.1616.15
86302.6224.27
68203.0637.30
50103.7058.75
3203.9765.85
14-104.4278.19
-4-204.8790.54
-22-304.89102.88
-40-404.91115.23

Values were calculated for VREF=5.0 volts.These values may vary 15 percent due to sensor and VREF variations.

Article & images courtesy of fordfuelinjection.com.

Related Posts
Ford EcoBoost engine
Ford EcoBoost engine

The 1.6 L 3 cylinder turbocharged EcoBoost engine is an upcoming design in a number of Ford vehicles wearing the Read more

Common Ford power steering issues
Common Ford power steering issues

Common Ford power steering issues Ford power steering pump with reservoir. The power steering system commonly found on most Ford Read more

Ford MTX-75 transmission
Ford MTX-75 transmission

The Ford MTX-75 (Manual TransaXle), is a 5-speed transmission developed by Ford Motor Company for its larger engined front wheel drive models. "75" refers to Read more

Ford Windstar modifications
Ford Windstar modifications

This page contains some modifications that were done to a Ford Windstar with a 3.8 Ford Essex engine for amusement. Read more

Similar Posts